Air Handling Units (CAM)

The Conditioned Air Module (CAM) unit is a modular zonal air handling unit which takes in air from the floor void and returns it to the space fully treated and conditioned.  It’s compact design allows it to be located free standing within the working environment, or placed within cupboard space, corridors or in a small plant room

dx-camModel shown: DX CAM

With the Flexible Space System, the building is divided up into several zones per floor, divided into supply and return channels using air segregation baffle. Each CAM unit serves one zone, of between 100 – 300 m², and the conditioned air is distributed to the workspace via the low pressure plenum and into the space using fan terminal units

CAM

 

 

 

CAM-C sizes: CAM C-15 / CAM C-25 / CAM C-35

The CAM-C unit with underfloor supply and underfloor return is the most flexible option allowing total elimination of ceiling based duct work, enabling reduced slab to slab height, enhanced ventilation and comfort

CAM-V sizes:  CAM-V11 / CAM-V22 / CAM-V33 / CAM-V44

The CAM-V unit with underfloor supply and ceiling or high level return allows the return air to be drawn out through the false ceiling with no requirement for underfloor baffle, allowing use of the larger surface of floor slab to distribute the supply air, increasing the effect of thermal mass storage

Baseframes

CAM-C baseframe options are available to divide supply and return air channels and to accommodate different airflow patterns for any architectural or building design layout need

baseframe

The CAM-V baseframe is located within the raised floor, and has no provision for direct connection to ducting or piping. Piping is assumed to be routed through the front opening of the baseframe

Power, Controls and Communications:

CAM_control-panel

Each CAM is supplied with a complete internal wiring loom connecting all fitted electrical elements. A gland is provided for the incoming power and control wiring.  A factory-wired terminal board is isolated from the airflow, and includes an internal isolator for the complete isolation of the unit during maintenance

Supply and return sensors are supplied with the units along with a length of two core control cable. Automatic control of the unit is enabled via the Flexface board. Visualisation of the controls is through a Flexmatic display unit providing easy access to set point adjustment and other functions

Hard-wired connections for remote starting/stopping plus common alarm signals are standard features of all CAM’s, but comprehensive communication with most Building Management Systems (BMS) can be achieved using a Flexgateway module

 

 

 

CAM Features

  • Compact, free standing design
  • Silent vibration free operation
  • One unit serves a zone of up to 300 sq m
  • Cooling capacities from 5kW to 33kW
  • Airflow from 4000 m3/h to 9500
  • EU5 class filters as standard
  • 3 row coil as standard
  • AC / EC Fan options
  • DX coil option
  • Optional 1 row coil for hot water supply
  • Optional 2 stage electric heater
  • Optional humidity control
  • Communication via Flexmatic display
  • Network configuration via Flexgateway
  • Easy access for maintenance
  • 6 baseframe designs to suit air distribution layout (CAM-C)

 

FSS Components

Back to AET Flexible Space System

 

Zonal Systems

CAM-C: under floor supply and return

CAM-V: under floor supply, high level return

 

cam_freestanding

Free standing CAM units

 

cam_perimeter

CAM units at perimeter

 

Related Articles

Enhanced Versatility with DX Under Floor Cooling

New DX Options for AET Flexible Space