Case Study

| all |

The Hoxton (Wedge House)

Southwark, London, UK

The Hoxton Hotel incorporates 192 hotel rooms, restaurants, bars and function rooms, as well as 4,000m2 of flexible co-working office space, the all within a sleek and contemporary building.

Total Area

3500 m2

System
CAM-V - floor supply, high-level return

2020 Refurbishment

The Hoxton, Southwark, is an ambitious new refurbishment of a former social security office located on London’s south bank.

The Hoxton Hotel incorporates 192 hotel rooms, restaurants, bars and function rooms, as well as 4,000 m2 of flexible co-working office space, the all within a sleek and contemporary building.

The first two storeys of the new building contain public areas for the hotel. Six floors of hotel rooms provide 192 rooms, and a further five floors of flexible office space provide new offices for start-ups and sole traders, with a winter garden breakout space for workers to mingle on the 12th floor and a 14th-floor, top-floor bar and restaurant.

AET’s flexible and adaptable CAM-V underfloor air conditioning system was identified by the M&E consultants Hoare Lea and subsequently chosen by the project team as the most suitable solution for the 5 floors of office space. The Hoxton Hotel office space will primarily be used for co-working, with regular changes to layout and function, therefore finding and air conditioning system that could be easily adapted to the ever changing needs of the space was essential.

AET’s modular Fantile units fit seamlessly and can be quickly and easily relocated. AET’S UfAC systems make use of the void beneath the raised floor void, as a plenum, where conditioned supply is distributed, whilst drawing spent room air back to the Conditioned Air Module (CAM) unit at high level by way of return air grille.

The conditioned air is delivered into the space, by induction, via AET’s unique Fantile units, which fit seamlessly into the sub-structure of the raised access floor, and can be quickly and easily relocated at any time.

As the floor plenum is 100% supply air the CAM-V system offers maximum flexibility to the space in terms where the Fantile units can be placed, allowing for effortless reconfiguration depending on the particular needs of the layout office.

The standard TU4 Fantile units were used throughout the majority of the office space, while AET’s specially designed slimline TU350 Fantile units were used within the central break-out and kitchen areas on each floor. This was due to a reduced 170mm floor void in these areas, which was a result of the design of the building’s structure.

Developer – Enismore (The Hoxton Group)

Architect – Lifschutz Davidson Stanilands

M&E Consultant – Hoare Lea

Quantity Surveyor – Gardiner & Theobald

Main Contractor – Kier

M&E Contractor – Jll Ltd.


Case Study PDFs

Contact us at sales@flexiblespace.com to request PDF case studies

Shatin Industrial Centre

Underfloor air conditioning was specified for the project at Shatin Industrial Centre, transforming the entire sixth floor into a co-working space specifically for a community of designers and architects.

Refurbishment

The Stills (76 Turnmill Street)

This comprehensive refurbishment of a drab, 1970s Government-owned office block (formerly Layden House) has transformed the façade and created 38,000 sq. ft of contemporary office space.

Refurbishment

SAS Marlow

Since the installation of AET’s UfAC system and completion of the fit-out works, SAS’s staff have been able to move back into their new office environment. Many of them have already commented on the vastly improved working conditions.

Refurbishment

Citygate House

AET’s system has formed a significant element of its refurbishment works, and has enabled the project team to maximise floor to ceiling heights.

Refurbishment

Contact us to discuss your HVAC requirements

See how UfAC can speed up construction time, reduce costs and create space.