CPD 1: UfAC vs Displacement Ventilation.

…automatic fan speed control and the resulting increase in ventilation rate. Air returns to the zonal unit via air grilles positioned above the return air plenum in the raised floor. Fresh air may be introduced into the return plenum or directly to the unit, and exhaust air may be extracted…
(Search hits: 89 in body, 0 in title. Relevance score: 82909.69)

Fitout & Maintenance

…replacement TU4 Fantiles, return grilles, Flextouch wall controllers and sound attenuator boxes. Supply and install: 3 x TU4-EC Fantiles 5 x return air grilles 17 x sound attenuator boxes 5 x Flextouch wall controllers 315 480 1812 1813 1804 1809 1805 1806 1807 1808 1810 1811 1814 121 1742 1741…
(Search hits: 10 in body, 0 in title. Relevance score: 16209.44)

Hammersley House

Fan Coils. With underfloor systems, fully conditioned air is fed into the plenum by a zonal downflow units (CAM) serving areas up 300 sq m each. Conditioned air is then supplied into the workspace via fan terminal units (Fantiles) recessed into the floor. Systems can be either chilled water or…
(Search hits: 16 in body, 0 in title. Relevance score: 8730.14)

Flexible Air Traffic Control for TAG Farnborough

…into supply and return air channels using easily relocatable, airtight baffles. Supply air is drawn up into the occupied space by fan assisted terminal units (TU4), which are recessed into the floor, plug into an underfloor power source and are connected by data cabling for intelligent control. These fan tile…
(Search hits: 28 in body, 4 in title. Relevance score: 8571.58)

Take Control of your Indoor Environment using Under Floor Air Conditioning

…commonly used in office environments, utilising the plenum beneath a raised floor as the ventilation zone. Fully conditioned air is fed into the plenum by zonal downflow units (CAM), and then supplied into the workspace via fan terminal units; more commonly known as a “Fantile”. The plug and play fantiles…
(Search hits: 30 in body, 1 in title. Relevance score: 8357.56)

CAM-C Zonal System

…to be interchangeable with standard 600mm floor panels. Air Segregation Baffle 1144 Fire-resistant and airtight fabric made from glass fibre cloth which is used to divide the underfloor plenum into supply and return air channels. Fresh Air Module 1142 The fresh air model FA7/FA5 draws additional fresh air from outside…
(Search hits: 3 in body, 0 in title. Relevance score: 8011.54)

Plenum Air Conditioning for Refurbishment and Retrofit Projects

…give a general description of how plenum air conditioning works. In brief; fully conditioned air is fed into the underfloor plenum by zonal downflow units (CAM). The supply air is then introduced into the space via floor recessed fan terminal units (Fantile). Spent return air can be returned to the…
(Search hits: 28 in body, 1 in title. Relevance score: 7771.96)

The Hoxton (Wedge House)

…make use of the void beneath the raised floor void, as a plenum, where conditioned supply is distributed, whilst drawing spent room air back to the Conditioned Air Module (CAM) unit at high level by way of return air grille. The conditioned air is delivered into the space, by induction,…
(Search hits: 14 in body, 0 in title. Relevance score: 7559.04)

No.1 Cavendish Place

…relocatable, airtight baffles. Supply air is drawn up into the occupied space by Fantile units (FTU450), which are recessed into the floor. These Fantile units feature individual controls to provide variable speed and temperature adjusted for maximum user comfort. Air travels back to the CAM via return grilles located over…
(Search hits: 12 in body, 0 in title. Relevance score: 7346.14)

FlexTouch Remote Controller

…of fantile units. Underfloor air conditioning is commonly used in office environments, utilising the plenum beneath a raised floor as the ventilation zone. Fully conditioned air is supplied into the plenum by zonal downflow units (CAM), and is then supplied into the workspace via fan terminal units (Fantile). The fantile…
(Search hits: 25 in body, 0 in title. Relevance score: 6654.1)

10 St Giles Square

…the space by active Fantile™ units. Room air is drawn back to the CAM, for reconditioning, via passive, return grilles which are installed with the return path where it mixes with fresh air enabling the systems to achieve high standards of indoor air quality. The TU4 Fantiles™ were installed within…
(Search hits: 12 in body, 0 in title. Relevance score: 6387.97)

CAM-V Zonal System

Fantile (Fan Air Terminal) is designed to replace a standard 600mm x 600mm raised access floor panel and is recessed into the floor. It extracts conditioned air from the plenum below the raised floor and introduces it into the workspace. It also re-circulates room air. Fantiles feature two temperature sensors…
(Search hits: 2 in body, 0 in title. Relevance score: 6334.71)

76-88 Wardour Street overcomes height restrictions using AET Flexible Space

…supply and return air. Each floor was divided into two zones, each served by an AET downflow unit (CAM). The air is introduced into the space via a fan terminal or “Fantile” unit, which has the added benefit of individual personal control of air flow and temperature via the integrated…
(Search hits: 22 in body, 1 in title. Relevance score: 6228.22)

Bloomberg City Gate House

…steel cabinets. The air is delivered into the space by around 500 standard TU4 Fantile units. 13 Phased refurbishment for Bloomberg LP and Herbert Smith LLP at City Gate House 39-45 Finsbury Square 1996 – 2006 Flexible Space Under Floor Air Conditioning was supplied to create a high level of…
(Search hits: 9 in body, 0 in title. Relevance score: 6174.98)

AET Flexible Space at No. 1 Cavendish Place

…height. Each zone is supplied with chilled or warmed air by conditioned air module (CAM). The underfloor void is divided into supply and return air channels using easily relocatable, airtight baffles. Supply air is drawn up into the occupied space by fan assisted terminal units (TU4), which are recessed into…
(Search hits: 21 in body, 1 in title. Relevance score: 5962.07)

One Benjamin Street, London

…stage 3 design. Each CAM unit is served by a high efficiency, roof-mounted heat pump unit. A total of 105 TU4-EC Fantile units deliver conditioned into the air into the space from the 270mm floor void. AET’s CAM-V system offers 100% flexibility in terms of where a Fantile units can…
(Search hits: 11 in body, 0 in title. Relevance score: 5962.07)

Energy Efficiency Award for Latvian Bank HQ

…is divided into a number of air-conditioning zones depending on the potential use and occupancy density of the area, with each zone supplied with chilled or warmed air by a conditioned air module (CAM). The underfloor void is split into supply and return air plena using easily relocatable, airtight baffles….
(Search hits: 22 in body, 0 in title. Relevance score: 5962.06)

AET FlexTouch Controller now with CO2 Mode Control

…environments, utilising the plenum beneath a raised floor as the ventilation zone. Fully conditioned air is supplied into the plenum by zonal downflow units (CAM), and then supplied into the workspace via fan terminal units (Fantile). The Fantile units feature integrated controllers where users can personally adjust fan speed and…
(Search hits: 22 in body, 0 in title. Relevance score: 5962.05)

Exposed Ceilings and Plenum Air Conditioning: A Perfect Partnership

fan coils as they virtually eliminate the possibility of retaining the architectural detail. Other benefits of Under Floor Air Conditioning include excellent indoor air quality and the ability to introduce fresh air into a building without experiencing loss of some of the fresh air before it is adequately mixed into…
(Search hits: 21 in body, 1 in title. Relevance score: 5962.04)

AET Flexible Space Returns to First Point, Gatwick Airport

AET Flexible Space, manufacturer and supplier of under floor air conditioning (UfAC) systems has received an order for replacement equipment for the second floor of the First Point Buckingham Gate building at Gatwick Airport. Originally constructed by BAA Lynton in the late 1990’s and equipped throughout with AET Flexible Space…
(Search hits: 20 in body, 1 in title. Relevance score: 5749.15)

Specifying a Low Level Services Strategy

…they focus on people and process, HR and lease terms rather than building services functions. At AET, we manufacture the “Flexible Space System”, which is arguably, “the original underfloor air conditioning system”. Flexible by name and flexible by nature, underfloor equipment is not capable of being bent, nor is it…
(Search hits: 21 in body, 0 in title. Relevance score: 5695.88)

Super Slim-line Fantile Launched by AET Flexible Space

AET Flexible Space, leading provider of underfloor air conditioning systems has just released the latest version of their market leading recessed fan air terminal, or Fantile. The new super slim-line TU350 Fantile is similar to the existing TUS Fantile, with an equivalent unit height of just 160mm, but the new…
(Search hits: 17 in body, 3 in title. Relevance score: 5482.96)

Great Portland Street Refurbishment wins BCO Innovation Award

…warmed air by a conditioned air module (CAM). The underfloor void is divided into supply and return air channels using easily relocatable, airtight baffles. Supply air is drawn up into the occupied space by fan assisted terminal units (TU4), which are recessed into the floor, plug into an underfloor power…
(Search hits: 20 in body, 0 in title. Relevance score: 5376.52)

Prestigious New Build in Ghana Chooses Under Floor Air Conditioning

…AET CAM-V33 units. The air is introduced into the space via a fan terminal or “Fantile” unit, which has the added benefit of individual personal control of air flow and temperature via the integrated Fatronic controller, and this building is served by more than nine hundred standard TU4 fantile units….
(Search hits: 18 in body, 1 in title. Relevance score: 5163.56)

City of London Refurbishment benefits from Under Floor Air Conditioning

…module (CAM) and this conditioned air is then supplied into the work space using a Fan Terminal Unit (Fantile). This project was among the first to use AET’s new slimline unit incorporating EC Fan technology. The TUS-EC unit can be used in a floor void with as little as 170mm…
(Search hits: 18 in body, 1 in title. Relevance score: 5163.56)

Contact us to discuss your HVAC requirements

See how UfAC can speed up construction time, reduce costs and create space.