You searched for flexible-air-traffic-controls-fan-tu4-farnborough — Page 3 of 7 — AET Flexible Space
Search

Jaguar Land Rover Design Centre

…BIFM “Office of the Year” awards 13 The building has over 40 zones with AET Flexible Space CAM-C25 and CAM C-35 downflow units supplying conditioned air into the plenum beneath the raised access floor. Conditioned air is introduced into the work space by more than 750 Fantile units. The site…
(Search hits: 6 in body, 0 in title. Relevance score: 4045.72)

Air Conditioning Commercial Office Space

Air Conditioning Commercial Office Space. Floor level services offer optimum flexibility for speculative tenancy and future change of use. AET Flexible Space underfloor air conditioning: less waste, a better use of space….
(Search hits: 13 in body, 1 in title. Relevance score: 3886)

180 Great Portland Street

…floor, removing the need for any ceiling-based services and so maximising floor to ceiling heights. Chilled or warmed air is provided by the conditioned air module (CAM). The underfloor void is divided into supply and return air channels, and supply air is drawn up into the space by Fantile units…
(Search hits: 7 in body, 0 in title. Relevance score: 3832.79)

33 Glasshouse Street Refurbished with Under Floor Air Conditioning

…to seven. Space saving underfloor air conditioning has been specified by Consultants WPP and Architects Buckley Grey Yeoman. With underfloor systems, fully conditioned air is fed into the plenum by zonal downflow units (CAM), which is then supplied into the workspace via fan terminal units (Fantile). The fantile units feature…
(Search hits: 13 in body, 1 in title. Relevance score: 3832.75)

Sustainable Flexible Cooling for MAF Properties Headquarters

…and economical to adapt to changes in the workplace. The conditioned air is introduced into the space via floor recessed fan terminal units or Fantiles, which are easily relocated with the 600 x 600mm raised floor tiles and also feature integrated controllers allowing users to personally adjust temperature and fan
(Search hits: 13 in body, 1 in title. Relevance score: 3832.75)

Sir William Perkin Sixth Form Centre opts for UfAC

…study centres. With AET Flexible Space systems, fully conditioned air is fed into the plenum by zonal downflow units (CAM), which is then supplied into the workspace via fan terminal units (Fantile). The fantile units feature integrated controllers where users can personally adjust fan speed and temperature to suit their…
(Search hits: 14 in body, 0 in title. Relevance score: 3779.52)

The Gilbert & One Lackington

…the year 2002. A total of 8 CAM-C units were installed around the perimeter of each floor plate providing 24-hour cooling to the densely populated office floors, which in turn were served by AET’s standard TU4 Fantile™ units and slim line TU3 units on the 4th and 5th floors, due…
(Search hits: 7 in body, 0 in title. Relevance score: 3726.3)

University of Essex

…with high levels of fresh air to the mixed-use space. The client preferred a flexible system which would satisfy both high and transient occupancy levels and adapt to future change of use within the space. The project was the first to install the new TU4-EC Fantile, the standard fan terminal…
(Search hits: 5 in body, 0 in title. Relevance score: 3726.3)

SAS Marlow

…an underfloor air conditioning system is that it avoids uncomfortable and unwanted cold drafts from the ceiling. AET’s Fantile™ units induce conditioned air into the space, drawing room air into a plume as it rises into the space making for a more gradual, unobtrusive air flows compared to conventional ceiling-based…
(Search hits: 7 in body, 0 in title. Relevance score: 3726.28)

Building Tall with Underfloor Air Conditioning

…in dense urban locations with poor outdoor air quality. The zoned nature of underfloor systems means that fresh air can easily be introduced directly into the system to enhance indoor air quality and with each zone served by an individual downflow unit, cross contamination is reduced. Taking an example from…
(Search hits: 13 in body, 1 in title. Relevance score: 3726.27)

Oak Finish Raised Flooring for No.1 Cavendish Place by AET Flexible Space

AET Flexible Space leading manufacturer and supplier of Under Floor Air Conditioning (UfAC) systems originally supplied 1500 m2 of high specification Nesite Raised Access flooring over four floors at No. 1 Cavendish Place in 2001, in conjunction with AET Flexible Space air conditioning equipment. This year AET have re-supplied the…
(Search hits: 12 in body, 1 in title. Relevance score: 3566.59)

Under Floor Air for Surrey University

Advanced Ergonomic Technologies Ltd (AET), the manufacturer and supplier of the Flexible Space System, its market leading underfloor air-conditioning system, has successfully completed a project for the University of Surrey. At the centre of the University’s Stag Hill campus, the instantly recognisable gold and glass framed library, which seats over…
(Search hits: 12 in body, 1 in title. Relevance score: 3566.58)

Flexible Space Distribution

Underfloor air conditioning is available worldwide through our approved partners. New Distributors and Agents always welcome – Contact Us AET HQ Lucy Jeffrey 44 (0)1342 310400 https://www.flexiblespace.com 3 AET Flexible Space (Hong Kong) Ltd 99 Queen’s Road Central, Central, Hong Kong 22.284616 114.15474500000005 Mr Waigo Ng 0085 25752181 http://www.aet.com.cn EKA…
(Search hits: 1 in body, 1 in title. Relevance score: 3539.97)

Underfloor Air Conditioning fits the bill at 8 Waterloo Place

…ventilation zone. This zone is divided into supply and return air paths using airtight relocatable baffle and then the CAM receives spent air back at floor level for re-conditioning, allowing the total elimination of services located in the ceiling. Conditioned air is fed into the space using modular, plug and…
(Search hits: 12 in body, 1 in title. Relevance score: 3513.36)

New Mobile App for User Control of Underfloor Air Conditioning Systems

AET Flexible Space, leading provider of underfloor air conditioning (UfAC) systems can now offer even more personal user control with the newly launched “FlexApp”. AET Flexible Space systems have featured personal user control for thirty years, highlighting the advanced and user led design of their underfloor systems and this latest…
(Search hits: 12 in body, 1 in title. Relevance score: 3513.35)

The Willis Building

The Willis Building in Ipswich originally constructed in 1974 and credited with listed status in 1991 undertook extensive refurbishment in 1999 including the installation of under floor air conditioning to create additional office space The AET Flexible Space system was specified by FC Foremans as a solution to overcome English…
(Search hits: 5 in body, 0 in title. Relevance score: 3513.34)

AET Newsletter December 2019

…by a zonal air handling unit or CAM (Conditioned Air Module) and the conditioned air is then delivered into the space using a number of recessed fan terminals (Fantile™). One Benjamin selected AET’s most flexible system, the CAM-V, which makes use of the raised floor void as a plenum for…
(Search hits: 13 in body, 0 in title. Relevance score: 3460.12)

New Tenant Fit-out at 6 Warwick Street

…is a CAM-V direct expansion (DX) system, with underfloor supply air and return air at high level. The high level return air option can offer greater flexibility for positioning Fantiles for future and speculative tenants as there is no air segregation baffle dividing the underfloor plenum. The fourth floor with…
(Search hits: 13 in body, 0 in title. Relevance score: 3460.11)

Frequently Asked Questions

…Cooling depends on space temperatures, water temperatures, water flows etc. but generally the AET Flexible Space system can accommodate loads of up to 200 W/sq m. AET will select CAM’s and specify the number of Fantiles required. Do the Fantiles cause draughts? If the fan terminals are correctly located, draughts…
(Search hits: 1 in body, 0 in title. Relevance score: 3353.65)

24 St James’s Square

AET Flexible Space was specified to supply its innovative CAM-V underfloor air conditioning (UfAC) system for the refurbishment of 24 St James’s Square, completed in early 2020. The design brief was to maximise floor-to-ceiling heights and enhance the double aspect interior. One of the key challenges was the need to…
(Search hits: 6 in body, 0 in title. Relevance score: 3300.42)

Underfloor Air Conditioning Fit-out at Hanover Street

…underfloor plenum. This conditioned air is supplied into the workspace via fan terminal units, known as Fantiles which are recessed into the floor plenum. Approximately 80 standard size TU4 Fantiles are located over the building’s five floors and a fully stringered Nesite raised access flooring system supplied by AET is…
(Search hits: 11 in body, 1 in title. Relevance score: 3300.42)

72 Broadwick Street

…unique Fantile units, which are fitted seamlessly into the building’s raised access floor. A total of 170 TU4 EC Fantile units will be installed across the floor plate, and these can be easily repositioned in minutes to suit varying office layouts. Implementing a sustainable design was also a key consideration….
(Search hits: 6 in body, 0 in title. Relevance score: 3193.97)

77 Coleman Street

…7, utilising high-efficiency, roof-mounted heat pump units. Each floor is served by 4 CAM units, and conditioned air is fed into the space via 48 floor-recessed TU4 Fantile™ fan terminal units. AET’s unique Fantile™ units work to eliminate cold drafts for high level, as well as providing superior end user…
(Search hits: 6 in body, 0 in title. Relevance score: 3193.96)

First Point Building, Gatwick

…rental income. In 2015 AET returned to First Point to carry out equipment upgrades. 20 13 Flexible Space Under Floor Air Conditioning was specified for this new build development originally completed in 1998 after BAA Lynton carried out a feasibility study, comparing underfloor air conditioning against ceiling based air conditioning…
(Search hits: 4 in body, 0 in title. Relevance score: 3087.49)

Microsoft Shanghai

Each floor is divided into 50 zones with an AHU supplying underfloor air to the recessed Fantile units. Construction time was reduced to five months and the owner-occupiers benefit from a flexible, user friendly system providing a high level of indoor air quality. 16 A five storey new build construction…
(Search hits: 5 in body, 0 in title. Relevance score: 3087.49)

UfAC for Centrica Energy Aberdeen Headquarters

…units (CAM) supply treated conditioned air into the plenum which is then introduced into the workspace via floor recessed fan terminal units known as Fantiles. The Fantiles are interchangeable and easily relocated, replacing standard 600 x 600 mm raised floor tiles. They also feature integrated controllers allowing users to personally…
(Search hits: 11 in body, 0 in title. Relevance score: 3034.26)

Contact us to discuss your HVAC requirements

See how UfAC can speed up construction time, reduce costs and create space.