You searched for sky-control-campus — Page 2 of 3 — AET Flexible Space
Search

77 Coleman Street

…comfort and control. Completion of this building is expected in early summer 2020. Moorgate, London, UK 2020 6300 m2 CAM-V – floor supply, high-level return 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 Investor/Developer – Kajima Properties Architect – Buckley Gray Yeoman M&E Consultant – The GDM…
(Search hits: 1 in body, 0 in title. Relevance score: 532.34)

24 St James’s Square

…the refurbishment, were variations in temperature across the office space, high level cold draughts and a lack of natural daylight light. An UfAC solution however, provides greater individual control of localised temperature, unobtrusive movement of air and makes for a more comfortable, brighter working environment. The 24 St James’s Square…
(Search hits: 1 in body, 0 in title. Relevance score: 532.34)

AET Newsletter March 2020

…AET’s unique control solution it is possible to set the temperature and air flow to zone requirements. AET’s UfAC solution is designed to create minimal draughts and allow for individual control of temperature and fan speeds, creating comfortable and adaptable working environments throughout the office space. The 24 St James…
(Search hits: 2 in body, 0 in title. Relevance score: 532.34)

Specifying a Low Level Services Strategy

…draughty, with little or no control over air temperature. Indoor air quality is also compromised as contaminants that can collect at ceiling level are repeatedly circulated back into the breathing zone by the downward flow of air. With underfloor systems, contaminants are forced to the ceiling and re-entry is avoided…
(Search hits: 2 in body, 0 in title. Relevance score: 532.34)

77 Farringdon Road

…building owners, NFU mutual, and the building now offers six floors of warehouse style accommodation, featuring exposed brickwork walls and optimum natural light due to the prominent corner position. AET Flexible Space supplied upgraded control boards for the existing zone downflow units and 140 new Fantiles for the speculative Category-A…
(Search hits: 1 in body, 0 in title. Relevance score: 532.34)

Korea Expressway Corporation

…large size CAM-V downflow units supply air at volumes of up to 16,500 m3/hour. The building also uses the AET Flexvisor monitoring system for remote monitoring and control. Underfloor systems were preferred by the client due to the height saving capabilities, flexibility and speed of installation. AET CAM-V100 and CAM-V150…
(Search hits: 1 in body, 0 in title. Relevance score: 532.34)

Bridge House

…filtered, reconditioned and redistributed back into the floor void. The adaptability of AET’s UfAC system will give the incoming tenants complete control over how they use the office space by allowing them to quickly and easily reposition the Fantile™ units to suit their CAT-B layouts making for a more cost…
(Search hits: 1 in body, 0 in title. Relevance score: 532.34)

Great Portland Street Refurbishment wins BCO Innovation Award

…source and are connected by data cabling for intelligent control. These fan tile units feature individual controls to provide variable speed and temperature adjusted locally for maximum user comfort. Air travels back to the CAM via return grilles located over the return channel for re-conditioning and is mixed with fresh…
(Search hits: 2 in body, 0 in title. Relevance score: 532.34)

Energy Efficiency Award for Latvian Bank HQ

…refurbishment project prior to the competition, sustainable solutions provider, AET, supplied the Nordea Bank building with its Flexible Space Underfloor Air Conditioning System for optimum low energy performance, temperature comfort and control. As part of the energy efficient HVAC system for the building, Flexible Space has enabled Nordea Bank to…
(Search hits: 2 in body, 0 in title. Relevance score: 532.34)

CAM-C Zonal System

…up to 2.5kW is achieved with a nominal airflow of 500m3/h. Options include standard or slim-line units, AC or EC fans, electric trim heaters and hot water coil. A minimum clearance of 180mm is required under the floor. Controls Units Components Components Components Components Components Controls Controls Units Units cam-c/…
(Search hits: 0 in body, 0 in title. Relevance score: 372.64)

CAM-V Zonal System

…for areas unsuitable, or with inadequate space for recessed terminals. The unit is positioned over an opening in the raised floor, extracts conditioned air from the plenum and delivers it into the space. Add more detail in accordance with Fantile text? Controls Units Units Components Components Controls Controls Units cam-v/…
(Search hits: 0 in body, 0 in title. Relevance score: 372.64)

Under Floor Air for Surrey University

Advanced Ergonomic Technologies Ltd (AET), the manufacturer and supplier of the Flexible Space System, its market leading underfloor air-conditioning system, has successfully completed a project for the University of Surrey. At the centre of the University’s Stag Hill campus, the instantly recognisable gold and glass framed library, which seats over…
(Search hits: 1 in body, 0 in title. Relevance score: 266.2)

UfAC for Korea Expressway Headquarters

…The conditioned air is introduced into the space via floor recessed fan terminal units or Fantiles, which are easily relocated with the 600 x 600mm raised floor tiles and also feature integrated controllers allowing users to personally adjust temperature and fan speed settings. The CAM-V units introduce conditioned air at…
(Search hits: 1 in body, 0 in title. Relevance score: 266.2)

76-88 Wardour Street overcomes height restrictions using AET Flexible Space

…supply and return air. Each floor was divided into two zones, each served by an AET downflow unit (CAM). The air is introduced into the space via a fan terminal or “Fantile” unit, which has the added benefit of individual personal control of air flow and temperature via the integrated…
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

AET’S underfloor air conditioning technology shortlisted for Sustainability Award

…floor and can be repositioned within minutes, to suit ever changing office layouts, without the high costs associated with moving or altering ceiling-based systems. This flexible approach gives the end-users of office spaces complete control over how they are used, and ensure a longer lifetime for the air conditioning system….
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

Historic 196 Deansgate in Manchester Adopts Under Floor Air Conditioning

…system utilises the plenum as the ventilation duct, yet differs to standard underfloor air distribution; offering superior zonal control. As the system utilises the space beneath the raised access floor to distribute conditioned air, this eliminates the need for ceiling based duct work and offers a variety of benefits; for…
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

Savile Row Refurbishment Overcomes Height Restrictions with AET Flexible Space

…or Fantiles, which are easily relocated with the 600 x 600 mm raised floor tiles and also feature integrated controllers allowing users to personally adjust temperature and fan speed settings. The CAM-C units introduce conditioned air at floor level into the plenum beneath the raised floor and then receive return…
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

Sir William Perkin Sixth Form Centre opts for UfAC

…two zones within the Sixth Form centre will be cooled by CAM-V33 downflow units, with conditioned air supplied into the space by thirty one (31) TU4-AC standard fan terminal. Users will have personal environmental control of fan speed and temperature by using adjustment features of the Fatronic controller integrated into…
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

Prestigious New Build in Ghana Chooses Under Floor Air Conditioning

…AET CAM-V33 units. The air is introduced into the space via a fan terminal or “Fantile” unit, which has the added benefit of individual personal control of air flow and temperature via the integrated Fatronic controller, and this building is served by more than nine hundred standard TU4 fantile units….
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

AET Newsletter December 2019

…office. For maximum flexibility each Fantile is supplied with onboard Fanspeed and Set Point adjustment, but in meeting rooms and cellular space AET offers Flextouch™ wall-mounted controllers which allow users not only to adjust the fan speed and temperature, but also CO2 and humidity monitoring and control. Headroom Height was…
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

Building Tall with Underfloor Air Conditioning

By adopting floor level services early on, designers can make best use of this space saving potential High rise buildings and skyscrapers increasingly dominate skylines all over the world, London for example has around 450 skyscrapers planned for the next few years. They have the ability to spearhead regeneration and…
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

TSSA move into new Headquarters at 17 Devonshire Square

…TUS Fantiles and six FlexTouch wall controllers for the Director’s offices, permitting remote temperature and fan speed adjustment of the Fantiles without having to physically access the integrated controller within the unit. The project is also the first to install the FlexTouch wall controller with CAM control, allowing users on…
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

Stunning 33 Glasshouse Street attracts leading tech giant

…cater to the proposed high density layout and accommodate the additional cooling requirements. The client also opted to install sound attenuator boxes beneath the grilles to minimise noise transfer between the open plan workspace and cellular meeting pods. User control of the UfAC system is enhanced by twenty one new…
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

Tenant fit-out at 180 Great Portland Street for SVC

…wall mounted Flextouch controllers, permitting remote temperature and fan speed adjustment of the Fantiles without having to physically access the integrated controller within the unit. The fit-out works were handed over and new tenant SVC occupied the space early this month and the final result is fabulous high end, comfortable…
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

UfAC Services Upgrade for The Bond Works, Farringdon Road

…bid to upgrade the existing downflow unit controls and replace all fan terminals on the six refurbished floors with AET Fantiles. With underfloor air conditioning systems, fully conditioned air is fed into the plenum by zonal downflow units (CAM), which is then supplied into the workspace via fan terminal units…
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

High Specification Category-B Fit-out for 8 Waterloo Place

…plan workspace, meeting rooms and Director’s offices. User control of the underfloor air conditioning system is enhanced by the addition of fourteen wall mounted Flextouch controllers, permitting remote temperature and fan speed adjustment of the Fantiles without having to physically access the integrated controller within the unit. The fit-out works…
(Search hits: 1 in body, 0 in title. Relevance score: 266.17)

Contact us to discuss your HVAC requirements